Electrochemistry on nanopillared electrodes

  • The addition of nanopillars to electrodes increases their electrochemical capabilities through an increase in electroactive surface area. The nanopillars can be applied on either cathodes or anodes to engage in reduction-oxidation reactions. This minireview summaries some work on cyclic voltammetry, chronoamperometry, impedance change on nanopillared surface and compared their electrochemistry behavior on planar surfaces.

    Citation: Chandni Lotwala, Hai-Feng Ji. Electrochemistry on nanopillared electrodes[J]. AIMS Materials Science, 2017, 4(2): 292-301. doi: 10.3934/matersci.2017.2.292

    Related Papers:

    [1] Christoph Nick, Helmut F. Schlaak, Christiane Thielemann . Simulation and Measurement of Neuroelectrodes Characteristics with Integrated High Aspect Ratio Nano Structures. AIMS Materials Science, 2015, 2(3): 189-202. doi: 10.3934/matersci.2015.3.189
    [2] Sumaiya F. Begum, Hai-Feng Ji . Biochemistry tuned by nanopillars. AIMS Materials Science, 2021, 8(5): 748-759. doi: 10.3934/matersci.2021045
    [3] Hai-Feng Ji, Morasae Samadi, Hao Gu, Veronica Tomchak, Zhen Qiao . Fabrication and applications of self-assembled nanopillars. AIMS Materials Science, 2017, 4(4): 905-919. doi: 10.3934/matersci.2017.4.905
    [4] Christian M Julien, Alain Mauger, Ashraf E Abdel-Ghany, Ahmed M Hashem, Karim Zaghib . Smart materials for energy storage in Li-ion batteries. AIMS Materials Science, 2016, 3(1): 137-148. doi: 10.3934/matersci.2016.1.137
    [5] Alexandre Lavrov, Kamila Gawel, Malin Torsæter . Manipulating cement-steel interface by means of electric field: Experiment and potential applications. AIMS Materials Science, 2016, 3(3): 1199-1207. doi: 10.3934/matersci.2016.3.1199
    [6] Claas Hüter, Shuo Fu, Martin Finsterbusch, Egbert Figgemeier, Luke Wells, Robert Spatschek . Electrode–electrolyte interface stability in solid state electrolyte systems: influence of coating thickness under varying residual stresses. AIMS Materials Science, 2017, 4(4): 867-877. doi: 10.3934/matersci.2017.4.867
    [7] Christian M. Julien, Alain Mauger . In situ Raman analyses of electrode materials for Li-ion batteries. AIMS Materials Science, 2018, 5(4): 650-698. doi: 10.3934/matersci.2018.4.650
    [8] Stephanie Flores Zopf, Matthew J. Panzer . Integration of UV-cured Ionogel Electrolyte with Carbon Paper Electrodes. AIMS Materials Science, 2014, 1(1): 59-69. doi: 10.3934/matersci.2014.1.59
    [9] Serguei Chiriaev, Nis Dam Madsen, Horst-Günter Rubahn, Shuang Ma Andersen . Helium Ion Microscopy of proton exchange membrane fuel cell electrode structures. AIMS Materials Science, 2017, 4(6): 1289-1304. doi: 10.3934/matersci.2017.6.1289
    [10] R.A. Silva, C.O. Soares, R. Afonso, M.D. Carvalho, A.C. Tavares, M.E. Melo Jorge, A. Gomes, M.I. da Silva Pereira, C.M. Rangel . Synthesis and electrocatalytic properties of La0.8Sr0.2FeO3−δ perovskite oxide for oxygen reactions. AIMS Materials Science, 2017, 4(4): 991-1009. doi: 10.3934/matersci.2017.4.991
  • The addition of nanopillars to electrodes increases their electrochemical capabilities through an increase in electroactive surface area. The nanopillars can be applied on either cathodes or anodes to engage in reduction-oxidation reactions. This minireview summaries some work on cyclic voltammetry, chronoamperometry, impedance change on nanopillared surface and compared their electrochemistry behavior on planar surfaces.


    1. Introduction

    Electrochemistry involves the study of the electrical aspect of chemistry, namely chemical reactions occurring on electrodes. The electrodes include both an anode and a cathode. The redox reactions at the electrodes involve the gain and loss of electrons at electroactive surfaces. Results of electrochemical analysis depend on the size of electrochemically active surface area [1,2].

    The use of nanopillars as a surface material for electrodes is widespread, and for a good reason. The electrochemical properties of nanopillars determine their applications, which range from biosensors to magnetic random access memory chips and from photovoltaic devices to flat panel displays. The introduction of nanopillars has three effects on the electrochemistry on electrodes: increasing surface area and electroactive surface area; enhancing the conductive capability; and lowering the double layer capacitance.


    1.1. Increasing Total Surface Area and Electroactive Surface Area

    Nanopillars provide increased surface area on electrodes, which leads to greater sensitivity and signal discrimination. Researchers have developed nanopillars on both cathodes and anodes with a higher total surface area and electroactive surface area than the flat surface. Because of an improved signal-to-background ratio, the nanopillar array electrodes are electrochemically favorable to use. They would be suitable for the detection of electrochemical and electrocatalytic behaviors [3].

    The electroactive surface area is different from the total surface area, as reported from several groups using various methods.

    The total surface area depends on the density and size of nanopillars. It can be calculated by using a simple geometrical method [4],

    Stotal   = S0   + 2 π nrl (1)

    where S0 is the geometric area of the electrodes, n refers to the number of nanopillars in the area, r is the radius of the nanopillars, and l is the height.

    As for the electroactive surface area, since the electrochemical processes occurring at the electrodes were found to be linear-diffusion-driven processes, Anandan et al. [4] used the Randcles-Sevcik equation to relate the peak current to the electroactive surface area since the peak current is proportional to the electrochemically active surface area for diffusion-based electrode reactions:

    IP   = 2.69 × 105An3/2D01/2C0v1/2 (2)

    where IP is peak current, C0 is the original concentration of the electrolyte used, n is the number of electrons involved in the reaction, v is the potential sweep rate, A is the electroactive surface area, and D0 is the diffusion coefficient of the electrolyte.

    In Anandan's work, the total surface area with nanopillars is 12 times greater than that of the electrode without nanopillars. The peak current of electrode with nanopillars [1451.8 µA/(mM·cm2)] is 7 times greater than that of the electrode without nanopillars [199.3 µA/(mM·cm2)], suggesting the electroactive surface area of nanostructured electrode is only 7 times greater than that of the planar electrode. The result demonstrated the difference between the total surface area and electroactive surface area of nanostructured electrodes.

    Zou et al. [1] also used the Randcles-Sevcik equation (equation 2) to calculate the electroactive surface area of their boron doped diamond nanopillar arrays on nanocrystalline diamond (ND) film electrodes, compared to that of planar boron doped ND film electrodes. In this case, the total surface area increased by 4 times for the electrode with nanopillars, but the nanopillars were found to only increase electroactive surface area by 42% compared to the flat electrode.

    These results suggested the shape, density, length, etc. of the nanopillars played important roles in determining the electroactive surface of the nanostructured electrodes.

    In another work, Schröper et al. also compared surface areas of gold nanopillars with planar gold electrodes [5]. In this system, Au-oxide reduction was used to measure the electroactive surface area through observation of charge transfer processes for diffusion controlled systems, where the access of analyte to the surface is controlled by semi-infinite planar diffusion. Based on the peak currents for diffusion limited electrode responses, the electroactive surface area of an electrode with nanopillars was found to be about 1.45 times that of one without nanopillars. Based on the non-diffusion controlled system, the electroactive surface area showed a 5.9 fold increase in surface area compared to planar electrodes. The electroactive surface area from non-diffusion controlled system seemed to be closer to the total surface area increase factor of 7.1 fold measured from SEM.

    Other surface bound redox system by Schröper et al. involved redox active species, such as hexacyanoferrate, K4[Fe(CN6)], and cytochrome c, on the surfaces. They compared the total surface area measured from SEM with electroactive surface area from different electrochemical measurements. The immobilized redox system had similar results, i.e., the non-diffusion controlled system provided an electroactive surface area number closer to the total surface area obtained from SEM, and in both cases, the electroactive surface areas on nanopillar electrodes are larger than those on a planar electrode.

    It was apparent from these experiments that the electroactive surface area does not equal the total surface area. One conclusion is that not all of the nanopillar surface is involved in the electrochemical reactions occurring on an electrode for diffusion controlled methods because of lack of accessibility to the entire nanopillar. The electroactive surface area values from non-diffusion controlled method was closer to the total surface area than diffusion controlled methods for determining electroactive surface area, although they too were not the most accurate for estimating total surface area.


    1.2. Enhancing the Conductive Capability

    In most, if not all cases, it is expected that the addition of nanopillars will improve the conducting capabilities of the surface. This is because that the quantum-sized dimensions of the nanopillar arrays result in greater electrocatalytic abilities than those on the flat electrodes [3]. At the tip of the nanopillars, the electric field emitted can be modeled by the equation:

    F = gVg   + hVa (3)

    where g and h are parameters (given as 1.6 × 108 m−1 and 2.5 × 107 m−1 respectively) that relate to specific electrode geometry, Vg is the gate voltage and Va is the anode voltage. While parameters like anode-cathode distance may vary, the equation should still provide a reasonable value [6]. The electrode geometry, used in the equation above, is one of the reasons for using nanopillars on cathodes. The geometric field enhancement factor resulting from nanopillars on cathodes leads to a lower turn on voltage for the devices, making the nanostructures a very appealing inclusion on various electronics [7].


    1.3. Decreasing Double-Layer Capacitance

    The nanoelectrode arrays are suitable for use in quick electrochemical measurements with high sensitivity because of their low double layer capacitance and low RC time constant [8]. Schröper et al. calculated double-layer capacitances (Cdl) by using the following equation [5]:

    CdlΔ I/2v (4)

    where ∆I is the current difference between positive and negative circular voltammetry cycles and v is the scan rate of the cycles. Compared to planar gold electrodes, nanopillar array electrodes have higher charging currents for double layer capacitance, i.e., lower double-layer capacitance, because of the surface modifications.

    In summary, nanopillar modified electrodes have demonstrated several advantages in electrochemistry compared to flat electrodes. The only disadvantage reported so far is the higher percentage of defect when modified with self-assembled monolayers (SAM), perhaps due to the shape of the nanopillars [9]. This review briefly summarizes recently studies in this area involving cyclic voltammetry, impedance, chronoamperometry, and cathodes and anodes with regards to nanopillars.


    2. Cyclic Voltammetry

    Cyclic voltammetry (CV) allows determination of redox peaks based on a potentiodynamic electrochemical measurement. By employing current measurement comparisons, it is feasible to determine whether nanopillar electrodes can serve as better electrodes, in terms of current and sensitivity, than planar ones. Some of the work from several groups are summarized in Table 1 and will be discussed in the following paragraphs.

    Table 1. The comparison of studies that used cyclic voltammetry for varying purposes.
    Authors Redox reaction Material, size, and density of nanopillars Results
    Zou et al. [1] [Fe(CN)6]3− and [Fe(CN)6]4− Diamond nanopillars with an average diameter of 130 nm and height of 900 nm The nanopillar array electrode displayed greater cathodic and anodic current responses than flat film electrode, with an increase in current density by 1.42 times.
    Valsesia et al. [8] hexacyanoferrate (Ⅱ/ⅡI) Polypyrrole (PPy) nanopillars with an average diameter of 60 nm for the 500 nm pattern and 171 nm for the 1000 nm pattern The CVs of the nanoelectrode arrays have the typical sigmoidal shape, but not the typical redox shape (Figure 1), so PPy nanopillar array is suited for fast electrochemical measurement. Surface areas were not compared.
    Leprince et al. [10] Redox of PPy. Electrical stimulus to release dexamethasone (DEX) Diameter of about 150 nm for the platinum nanopillars coated with polypyrrole The redox peaks occurred at lower values for the nanoelectrodes than the values for planar electrodes, which is due to the effects of nanopillars on the film's electrochemical properties. Surface areas are not compared.
    Shin et al. [3] Reduction of AuO at 0.9 V. H2O2, O2, dopamine, p-acetamidophenol, ascorbic acid, uric acid, Fe(CN)63−/4−, Ru(NH3)62+/3+ Au nanopillar array electrode (AuNPE) Electroactive surface area increases by 4.6 times for the AuNPE electrode when compared to a planar gold electrode. The diffusional redox peak current for these species are all higher and for the AuNPE compared to the bare Au electrode, but the rates are not much enhanced by the increased surface area.
     | Show Table
    DownLoad: CSV
    Figure 1. Cyclic voltammograms conducted in K3Fe(CN)6, with 1000 nm PPy nanopillars (dashed line), 500 nm PPy nanopillars (dotted line), and a uniform PPy surface (solid line).

    In general, planar electrode and nanopillared electrodes displayed similar electrochemical responses, but different amplitudes, on voltammograms. The results indicate that nanopillars speed up electron transfer and enhance the electrochemical response of a slow kinetic reaction.

    There are also cases the peaks shifted. For example, for the reduction of hydrogen peroxide and molecular oxygen, the reduction peaks on nanopillared surface were positively shifted compared to the peaks for a planar electrode (Figure 2) [3]. The reason for the shifts is most likely caused by the quantum sized dimensions of the nanopillars. Driskill-Smith et al. also looked into these quantum-interference effects [6], which occur between the anode and the electron wave function located on the tip of the nanopillar field emitter. They concluded that these effects cause time independent fluctuations in current-voltage characteristics in anodes.

    Figure 2. Cyclic voltammograms at Au nanopillar array electrode (solid line) and bare Au thin film electrode (dashed line). Electrolyte solutions: (a) 0.1 M PBS (pH = 7.0) containing 1 mM H2O2; (b) 0.1 M PBS saturated with O2 (30 min purging). All scan rates: 0.1 V·s−1.

    Shin et al. [3] showed that nanopillar electrode can discriminate species through voltammetric signals, something that was not seen in the bare Au thin film electrode. For example, the peak for the oxidation of glucose was distinct from the peaks from interfering compounds like ascorbic acid, acetamidophenol, and uric acid (Figure 3). These properties make the AuNPE electrode very promising for an electrochemical sensor.

    Figure 3. Left: CV at AuNPE (solid line) and bare Au thin film electrode (dashed line) in 0.1 M PBS (pH = 7.0) containing 1mM (a) dopamine (DO); (b) p-acetamidophenol (AP); (c) ascorbic acid (AA); (d) uric acid (UA). Right: CV at AuNPE (solid line) and bare Au thin film electrode (dashed line) in 0.1 M PBS (pH = 7.0) containing equimolar concentration of 0.5 mM dopamine and ascorbic acid. All scan rates: 0.1 V·s−1.

    Leprince et al. [10] employed CV to apply an electrical stimulus in order to trigger the release of dexamethasone (DEX) from the polypyrrole (PPy) coated nanopillar-electrodes (Figure 4).

    Figure 4. (A) The reduction reaction seen at the PPy/DEX film surface when electrically stimulated. (B) The oxidation reaction seen at the PPy/DEX film surface when electrically stimulated.

    The reduction peak on the voltammogram occurred at −0.2 V, while the oxidation peak occurred at 0.15 V for PPy/DEX films on electrode nanostructures; both peaks occurred at lower values for the nanoelectrodes than the values for planar electrodes. This lower value is attributed to the effects of nanopillars on the film's electrochemical properties, as an increase in electroactive surface area. A benefit of the lower peaks means release of DEX can occur at lower applied voltages. The amount released after 150 CV cycles for both a thick (700 mC/cm2) and thin (27.4 mC/cm2) PPy/DEX film is 106 and 39 µg/cm2, respectively. Those amounts are enough to trigger the anti-inflammatory effects of DEX on surrounding tissue.


    3. Impedance

    In electrochemical devices, high impedance results in low efficiency in signal transduction. In order to advance biosensors and biotechnology, researchers have been developing techniques to create nanoelectrodes with low impedance. The addition of nanopillars on electrodes has resulted in varying degrees of success. The investigation is ongoing for different dimensions and materials to create better nanoelectrodes with numerous applications.

    Xie et al. [11] created electrodes (Figure 5 left) for extracellular recording of action potentials and reported that by lowering impedance at the electrode-cell membrane connection, signal collection would become more efficient, allowing for accurate and long term signal recording. The vertically aligned nanopillars used created a tight cell-nanopillar electrode interface. Through transient electroporation, inducing nanometer sized pores in a membrane using a high electric field, the cell became more permeable. The decreased the impedance between the cell interior and the electrode resulted in a signal-to-noise ratio of 590, approximately 100 times of that of typical nanowire field-effect transistors. Xie et al. [11] also showed that electrical impedance of a chip with nanopillars noticeably decreased as more nanopillars were added (Figure 5 right).

    Figure 5. Left: SEM of 5 nanopillar electrodes on a platinum pad with a 350 nm Si3N4/SiO2 layer. Right: Measurement of electrochemical impedance at 1 KHz for 3, 5, and 9 nanopillar electrode arrays.

    Gardner et al. [12] reported the impedance decreases due to increasing nanopillar height of a Co-Ni-Cr-Mo (MP-35N) alloy and thus larger surface area. Previously, nanopillar height was between 1-3 μm. The increase in height from 1-3 μm to 10 μm reduced electrode impedance to about one fifth of the impedance in unprocessed MP-35N wires. This reduction holds true for signals under 100 Hz, in a phosphate-buffered saline solution. However, it should be noted that the increase in surface area significantly lowers impedance only at low frequencies due to high influence of electrode-electrolyte surface characteristics. At higher frequencies, increasing the surface area, while decreasing impedance, does not have as big of an effect because the dominate factor is the movement of ions in the electrolyte for the electrochemical activity on the nanopillar surface.

    Sanetra et al. [13] reported that thin coatings of under 100 nm of conductive polymer poly(3,4-ethylenedioxythiophene) with polystyrene sulfonic acid (PEDOT/PSS) on gold (Au) nanopillar electrodes (Figure 6) results in low impedance electrodes. Electrochemical impedance spectroscopy was performed to determine the impedance of PEDOT/PSS Au nanopillar electrodes versus polymer free planar gold electrodes and PEDOT/PSS planar electrodes. The nanopillars had an average diameter of 50 nm, height of 200 nm, and spacing of 30 nm. The conductive polymers are biocompatible and facilitate electron transfer between biological materials and electrodes. The polymer modified gold nanopillar electrodes had the lowest impedance. The contribution of increased electroactive surface area to decreased impedance was determined by double layer capacitance measurements. For a nanopillar electrode, it is found that the thinnest coating of the polymer results in a lower capacitance than a nanopillar electrode without the polymer coating because thin films can adapt to the nanopillar surface better and enhance electroactive surface area, and thus reducing impedance. With a coating of 30 nm, the Au nanopillar electrode had a decreased impedance by a factor 2.5 at 1 Hz when compared to the impedance of a PEDOT/PSS planar electrode. However, as polymer thickness increases, the coated nanopillar electrodes demonstrate higher capacitance than uncovered ones, because the surface area of nanopillars decreases with increased PEDOT/PSS coating thickness.

    Figure 6. Left: Impedance versus frequency for plain planar electrodes (black), PEDOT/PSS coated planar electrodes (red) and PEDOT/PSS coated Au nanopillar electrodes (blue). Right: Cross-sectional SEM of Au nanopillars spin-coated with a 28 nm polymers film (A and B) and a 120 nm polymer film (C and D).

    Also, there is a significant difference in impedance by a factor of 7 between uncoated planar gold electrodes and uncoated gold electrodes with nanopillars due to an increase in electroactive surface area.


    4. Chronoamperometry

    Another electrochemical test used on various nanopillar arrays is chronoamperometry, which measures current change as a function of time after a potential to cause an electrochemical reaction is applied to the working electrode. Anandan et al. [14] used it to determine the sensitivity of nanopillars. The onset of oxidation of K4Fe(CN)6 was 0.25 V, in reference to Ag/AgCl potential; the chronoamperometric tests were performed at that voltage. In a comparison of the responses exhibited by a gold plated nanopillar array electrode and a flat gold electrode, the gold nanopillar array displayed a steady state current eight times that of the flat electrode. This corresponds to the enhanced electrode sensitivity due to the nanopillars.


    5. Conclusion

    In conclusion, the addition of nanopillars to electrodes results in a higher electroactive surface area when compared to planar electrodes, resulting in greater electrochemical capabilities and more efficient electrodes. In many of these reactions, the nanopillars decreases the impedance and improves the functionality of the electrodes. Nanopillars also provide other advantages on electrodes, such as reducing cracking because of their smaller shape on a surface [15]. Because of its unique geometry, nanopillars on electrodes make them useful in a great deal of applications in electrochemical fields.


    Conflict of Interest

    The authors declare that there is no conflict of interest regarding the publication of this manuscript.


    [1] Zou YS, Yang Y, Zhou YL, et al. (2011) Surface Nanostructuring of Boron-Doped Diamond Films and Their Electrochemical Performance. J Nanosci Nanotechno 11: 7914–7919. doi: 10.1166/jnn.2011.4742
    [2] Yang MH, Hong SB, Yoon JH, et al. (2016) Fabrication of Flexible, Redoxable, and Conductive Nanopillar Arrays with Enhanced Electrochemical Performance. ACS Appl Mater Inter 8: 22220–22226. doi: 10.1021/acsami.6b06579
    [3] Shin C, Shin W, Hong HG (2007) Electrochemical fabrication and electrocatalytic characteristics studies of gold nanopillar array electrode (AuNPE) for development of a novel electrochemical sensor. Electrochim Acta 53: 720–728. doi: 10.1016/j.electacta.2007.07.040
    [4] Anandan V, Rao YL, Zhang G (2006) Nanopillar array structures for enhancing biosensing performance. Int J Nanomed 1: 73–79.
    [5] Schröper F, Brüggemann D, Mourzina Y, et al. (2008) Analyzing the electroactive surface of gold nanopillars by electrochemical methods for electrode miniaturization. Electrochim Acta 53: 6265–6272. doi: 10.1016/j.electacta.2008.03.068
    [6] Driskill-Smith A, Hasko D, Ahmed H (2000) Quantum interference in a vacuum nanotriode. J Vac Sci Technol B 18: 3481–3487. doi: 10.1116/1.1314388
    [7] Lewis PA, Alphenaar BW, Ahmed H (2001) Measurements of geometric enhancement factors for silicon nanopillar cathodes using a scanning tunneling microscope. Appl Phys Lett 79: 1348–1350. doi: 10.1063/1.1396821
    [8] Valsesia A, Lisboa P, Colpo P, et al. (2006) Fabrication of Polypyrrole-Based Nanoelectrode Arrays by Colloidal Lithography. Anal Chem 78: 7588–7591. doi: 10.1021/ac0609172
    [9] Ananadan A, Gangadharan R, Zhang G (2009) Role of SAM Chain Length in Enhancing the Sensitivity of Nanopillar Modified Electrodes for Glucose Detection. Sensors 9: 1295–1305. doi: 10.3390/s90301295
    [10] Leprince L, Dogimont A, Magnin D, et al. (2010) Dexamethasone electrically controlled release from polypyrrole-coated nanostructured electrodes. J Mater Sci 21: 925–930.
    [11] Xie C, Lin Z, Hanson L, et al. (2012) Intracellular recording of action potentials by nanopillar electroporation. Nat Nanotechnol 7: 185–190. doi: 10.1038/nnano.2012.8
    [12] Gardnera CJ, Trisnadia J, Kima TK, et al. (2014) Controlled metallic nanopillars for low impedance biomedical electrode. Acta Biomater 10: 2296–2303. doi: 10.1016/j.actbio.2013.12.046
    [13] Sanetra N, Feig V, Volfrum B, et al. (2011) Low impedance surface coatings via nanopillars and conductive polymers. Phys Status Solidi A 208: 1284–1289. doi: 10.1002/pssa.201001215
    [14] Anandan V, Rao YL, Zhang G (2005) Nanopillar Arrays with Superior Mechanical Strength and Optimal Spacing For High Sensitivity Biosensors. NSTI-Nanotech 3: 217–220.
    [15] Lee S, McDowell MT, Chooi JW, et al. (2011) Anomalous Shape Changes of Silicon Nanopillars by Electrochemical Lithiation. Nano Lett 11: 3034–3039. doi: 10.1021/nl201787r
  • This article has been cited by:

    1. Nongnoot Wongkaew, Marcel Simsek, Christian Griesche, Antje J. Baeumner, Functional Nanomaterials and Nanostructures Enhancing Electrochemical Biosensors and Lab-on-a-Chip Performances: Recent Progress, Applications, and Future Perspective, 2019, 119, 0009-2665, 120, 10.1021/acs.chemrev.8b00172
    2. Chuan Xiao, Yuming Zhao, Wei Zhou, Nanoimprinted conducting nanopillar arrays made of MWCNT/polymer nanocomposites: a study by electrochemical impedance spectroscopy, 2021, 3, 2516-0230, 556, 10.1039/D0NA00200C
    3. Yoo Min Park, Junhyoung Ahn, Young Sun Choi, Jae-Min Jeong, Seok Jae Lee, Jae Jong Lee, Bong Gill Choi, Kyoung G. Lee, Flexible nanopillar-based immunoelectrochemical biosensor for noninvasive detection of Amyloid beta, 2020, 7, 2196-5404, 10.1186/s40580-020-00239-2
    4. Love Bansal, Chanchal Rani, Tanushree Ghosh, Suchita Kandpal, Manushree Tanwar, Rajesh Kumar, Charge Storage Capabilities of Fractal Porous Silicon Obtained Using Simple Metal Assisted Porosification Method, 2023, 15, 1876-990X, 167, 10.1007/s12633-022-01965-4
    5. Love Bansal, Suchita Kandpal, Tanushree Ghosh, Chanchal Rani, Bhumika Sahu, Deb Kumar Rath, Rajesh Kumar, A supercapacitive all-inorganic nano metal–oxide complex: a 180° super-bendable asymmetric energy storage device, 2023, 2050-7526, 10.1039/D3TC02677A
  • Reader Comments
  • © 2017 the Author(s), licensee AIMS Press. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0)
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Metrics

Article views(5041) PDF downloads(928) Cited by(5)

Article outline

Figures and Tables

Figures(6)  /  Tables(1)

Other Articles By Authors

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return

Catalog