Biosensors based on lithotrophic microbial fuel cells in relation to heterotrophic counterparts: research progress, challenges, and opportunities

  • Biosensors based on the microbial fuel cell (MFC) platform have been receiving increasing attention from researchers owing to their unique properties. The lithotrophic MFC, operated with a neutrophilic iron-oxidizing bacterial community, has recently been developed and proposed to be used as a biosensor to detect iron, and likely metals in general, in water samples. Therefore, in this review, important aspects of the lithotrophic MFC-based biosensor, including its configuration, fabrication, microbiology, electron transfer mechanism, sensing performance, etc. were carefully discussed in comparison with those of heterotrophic (organotrophic) counterparts. Particularly, the challenges for the realization of the practical application of the device were determined. Furthermore, the application potentials of the device were also considered and positioned in the context of technologies for metal monitoring and bioremediation.

    Citation: Hai The Pham. Biosensors based on lithotrophic microbial fuel cells in relation to heterotrophic counterparts: research progress, challenges, and opportunities[J]. AIMS Microbiology, 2018, 4(3): 567-583. doi: 10.3934/microbiol.2018.3.567

    Related Papers:

    [1] Pontsho Patricia Twala, Alfred Mitema, Cindy Baburam, Naser Aliye Feto . Breakthroughs in the discovery and use of different peroxidase isoforms of microbial origin. AIMS Microbiology, 2020, 6(3): 330-349. doi: 10.3934/microbiol.2020020
    [2] Alexandra Soares, Ana Azevedo, Luciana C. Gomes, Filipe J. Mergulhão . Recombinant protein expression in biofilms. AIMS Microbiology, 2019, 5(3): 232-250. doi: 10.3934/microbiol.2019.3.232
    [3] O. Roger Anderson . Marine and estuarine natural microbial biofilms: ecological and biogeochemical dimensions. AIMS Microbiology, 2016, 2(3): 304-331. doi: 10.3934/microbiol.2016.3.304
    [4] Jane Tang . Microbiome in the urinary system—a review. AIMS Microbiology, 2017, 3(2): 143-154. doi: 10.3934/microbiol.2017.2.143
    [5] Zeling Xu, Shuzhen Chen, Weiyan Wu, Yongqi Wen, Huiluo Cao . Type I CRISPR-Cas-mediated microbial gene editing and regulation. AIMS Microbiology, 2023, 9(4): 780-800. doi: 10.3934/microbiol.2023040
    [6] Malin Bomberg, Mari Raulio, Sirpa Jylhä, Carsten W. Mueller, Carmen Höschen, Pauliina Rajala, Lotta Purkamo, Riikka Kietäväinen, Lasse Ahonen, Merja Itävaara . CO2 and carbonate as substrate for the activation of the microbial community in 180 m deep bedrock fracture fluid of Outokumpu Deep Drill Hole, Finland. AIMS Microbiology, 2017, 3(4): 846-871. doi: 10.3934/microbiol.2017.4.846
    [7] Arnab Bhowmik, Mara Cloutier, Emily Ball, Mary Ann Bruns . Underexplored microbial metabolisms for enhanced nutrient recycling in agricultural soils. AIMS Microbiology, 2017, 3(4): 826-845. doi: 10.3934/microbiol.2017.4.826
    [8] Paola Brun . The profiles of dysbiotic microbial communities. AIMS Microbiology, 2019, 5(1): 87-101. doi: 10.3934/microbiol.2019.1.87
    [9] Panayiotis D. Glekas, Olga Martzoukou, Maria-Eleni Mastrodima, Efstathios Zarkadoulas, Dimitrios S. Kanakoglou, Dimitris Kekos, Michalis Pachnos, George Mavridis, Diomi Mamma, Dimitris G. Hatzinikolaou . Deciphering the biodesulfurization potential of two novel Rhodococcus isolates from a unique Greek environment. AIMS Microbiology, 2022, 8(4): 484-506. doi: 10.3934/microbiol.2022032
    [10] Hisako Nakagawa, Tadaaki Miyazaki . Beneficial effects of antioxidative lactic acid bacteria. AIMS Microbiology, 2017, 3(1): 1-7. doi: 10.3934/microbiol.2017.1.1
  • Biosensors based on the microbial fuel cell (MFC) platform have been receiving increasing attention from researchers owing to their unique properties. The lithotrophic MFC, operated with a neutrophilic iron-oxidizing bacterial community, has recently been developed and proposed to be used as a biosensor to detect iron, and likely metals in general, in water samples. Therefore, in this review, important aspects of the lithotrophic MFC-based biosensor, including its configuration, fabrication, microbiology, electron transfer mechanism, sensing performance, etc. were carefully discussed in comparison with those of heterotrophic (organotrophic) counterparts. Particularly, the challenges for the realization of the practical application of the device were determined. Furthermore, the application potentials of the device were also considered and positioned in the context of technologies for metal monitoring and bioremediation.


    1. Introduction

    Biosensors are defined as devices that employ biological elements for sensing analytes to produce signals through their interactions with transducers [1]. Biological sensing elements can include enzymes, nucleic acids, antibodies or antigens, receptors, and microorganisms, as well as animal and plant cells and even whole organisms [1,2]. Among these elements, microorganisms appear to be more advantageous because: (i) they can detect a wide range of chemical substances, (ii) they are amenable to genetic modification, and (iii) they can operate in broad pH and temperature ranges. Furthermore, due to their microscopic size and high growth rate, they offer rapid and relatively precise responses to changes of the analytes to be sensed. Microorganisms have thus been used in a variety of biosensing systems with various types of signal transducing methods, including amperometric, potentiometric, calorimetric, conductimetric, colorimetric, luminescence-based, and fluorescence-based sensors [2]. Numerous publications and reviews have discussed those types of systems [1,2]. Recently, the emergence of microbial fuel cell technology has given rise to novel biosensors based upon microbial fuel cells [3,4,5,6,7,8], which offer a number of promising application potentials in practice, such as monitoring biological oxygen demand (BOD), detection of toxic metals and compounds, warning of dramatic changes of water treatment system inflows and outflows, monitoring microbial activities, and biofilm corrosion, etc. Microbial fuel cells (MFCs) are bioelectrochemical systems that operate with microorganisms acting as catalysts to convert chemical energy to electrical energy [9]. Although the possibility of using MFCs for harnessing power from waste appears very appealing, the technology has not been applied in reality due to the low maximum power output (per volume unit) of a MFC [10,11]. That is why other application potentials of MFCs, including the development of novel biosensors, have recently received more research attention [12,13,14,15,16,17]. In comparison to other types of microbial sensors, MFC-based biosensors offer advantages in that they can be self-powered and that they can produce electrical signals reflective of the metabolic rate of microorganisms, which can indicate the level of metabolized substrates. Moreover, MFCs directly generate electrical signals, eliminating the need for separate transducers, which is essential in other microbial sensor systems.

    Most MFC-based or bioelectrochemical (BES)-based biosensors reported thus far are operated with organic substrates as fuel, or electron donors [18,19]. These substrates are mostly artificial or real wastewater containing mixtures of organic compounds [18,19]. Thus, the sensing mechanism of those biosensors, whether to monitor the concentration of the analyte or to detect toxicity, is based on the microbial metabolism of organic matters. Indeed, a number of studies on those sensing systems have been reported and thoroughly reviewed [14,19]. In contrast, inorganic electron donors have been rarely examined in MFC-based sensors. Only recently have several MFC (or BES) systems operated with inorganic electron donors (substrates), such as sulfide, reduced inorganic sulfur compounds, ammonium, or metal ions, e.g. Fe2+, have been reported [20,21,22,23,24]. However, regarding their use as biosensors, only those operated with metal ions as electron donors have been studied [17,23]. These systems, in which electrons were generated by the chemolithotrophic metabolism of the anodic bacteria, should be designated as lithotrophic MFC-based biosensors. As these systems have only emerged recently, an overview of the current research in relation to that of their counterparts may be helpful. Therefore, this paper reviews ongoing research on lithotrophic MFC-based biosensors while comparing them with heterotrophic systems and extending the discussion on the challenges and opportunities for contextual application.


    2. Current discoveries

    Firstly, it should be noted that, as mentioned above, there has been a long history of extensive study on MFC-based biosensors, mostly involving those operated with heterotrophic microorganisms. Therefore, current discoveries of the lithotrophic MFC-based biosensor should be viewed in a comprehensive comparison with previous findings on these heterotrophic counterparts (Table 1).


    2.1. Device configuration and fabrication

    The first lithotrophic MFC-based biosensor proposed by Nguyen et al. (2015) was fabricated following the National Centre for Biotechnology Education (UK) (NCBE) model—a conventional design [23]. Basic materials for MFC assembly [25] were used, including polyacrylic as the frame material, graphite granules as the electrode material, and Nafion as the cation-exchanging membrane. The electrical signals can be monitored upon a voltage-based or a current-based manner. With such a design, the device was operated in batch mode, which provided for its function to sense Fe2+ and Mn2+ in water samples. Nevertheless, a special feeding scheme with a separate supply of the sample containing the metal ions was required in order for the device to work efficiently [23]. As the research on lithotrophic MFC-based biosensors is currently in an elementary phase, no further modified designs have been tested.

    It should be noted that several designs for MFC typed biosensors have been previously proposed. These include also a modified two-chamber NCBE-type design applied for a toxicity sensor [26]. The optimized two-chamber configuration and the so-called sensor-type configuration proposed by Kim et al. may enable a more responsive BOD sensor with less operational variations [27,28]. The air cathode or single chamber configuration, which was developed later, offers a more compact device with simpler operation and thus lower operational cost [4,29]. Recent attempts to create even more compact sensors eventually led to the development of microsized sensors [6,30,31]. The size and configuration of the latter were engineered so as to increase their response sensitivity and accuracy in addition to their practical application feasibility. It is therefore essential that innovative designs should also be included in experimentation for lithotrophic MFC-based biosensors in order to improve their performance.

    MFC-based biosensors can be operated in batch mode [29], but in most cases, they are operated in continuous mode, which is recommended to obtain more reliable signals and more importantly, to enable on-line monitoring [3,5,32]. Therefore, operating lithotrophic MFC-based biosensors in continuous mode may be a promising approach to enhance their sensing capacity.


    2.2. Electron donor

    The lithotrophic MFC-based biosensor proposed by Nguyen et al. (2015) is able to utilize ferrous iron as the electron donor [23]. The MFC generated an electrical current when it was operated with FeCl2 as the only possible electron donor at the anode and HCO3 as the carbon source [23]. It was later found that Mn2+ could also serve as an electron donor for such type of MFC, but the device did not seem to function well with a concentration of Mn2+ above 3 mM [17]. In addition, the presence of Ni2+ and Pb2+ might inhibit the electricity generation coupled with iron oxidation of the MFC. Organic electron donors were also tested in the MFC and did not appear to be the favored substrates [17]. Thus, Tran et al. (2015) claimed that the microorganisms in the MFC system might be so specialized in lithotrophy that their most favorable electron donors are metal ions.

    Table 1. A comprehensive comparison of the lithotrophic MFC-based biosensor and the heterotrophic counterparts.
    Compared factor Lithotrophic MFC-based biosensor Heterotrophic MFC-based biosensor
    Analyte Fe2+ (Mn2+) BOD, toxicity
    Electron donor Fe2+ (Mn2+) Organic compounds
    Configuration Modified NCBE type (two-chamber, square shape) Sensor-type [27,28]; single-chamber [4,29]; microsized reactor [6,30,31]
    Operational mode Batch Continuous
    Working microorganisms Bacterial community dominated by neutrophilic Pseudomonas sp. that possibly oxidize Fe2+ Various heterotrophic communities
    Possible electron transfer mechanism Indirect, via self-secreted mediators Various mechanisms: direct and indirect electrode interactions
    Sensing performance:
    • Shortest response time
    1 min 3 min
    • Detection range
    3-20 mM for Fe2+; 1-3 mM for Mn2+ 3-150 mg L−1 for BOD [3,26,27]; 0-350 mg L−1 for COD [30]; varying toxic compounds (lowest concentration detected: 1 µg L−1 for cadmium [30])
    • Specificity
    High Low; Acclimatized systems have high specificities [33,34]
    Challenges
    • Narrow detection range
    • Performance stability
    • Proper inoculation source
    • Limited specific detection
    • Performance stability
    References [17,23] [3,4,6,27,28,29,30,31,32,33,34]
     | Show Table
    DownLoad: CSV

    Indeed, MFCs operated with other inorganic electron donors have been also reported (Table 2). Rabaey et al. (2006) reported a MFC system operated with sulfide as an inorganic electron donor, but only able to be utilized in the presence of another organic electron donor, such as acetate [24]. Thus, this type of MFC is not a fully lithotrophic MFC. Interestingly, in a more recent study Zhong et al. (2017) reported a fully lithotrophic system operated with sulfide as the sole electron donor and nitrate as the electron acceptor [21]. Furthermore, other fully lithotrophic MFCs were also proven to be feasibly functional with inorganic sulfur compounds, such as tetrathionate, as the electron donors and ferric iron as the electron acceptor [20,35]. In another context, He et al. (2009) reported the development of a MFC with a rotating cathode that efficiently generated electricity while ammonium salts were present in the anolyte [22]. As those systems were not developed for use as biosensors, they will not be discussed further in this review.

    In heterotrophic MFC-based biosensors electron donors are, by default, organic compounds, which are actually BOD contents in wastewater in most cases [4,27]. In some laboratory-scale systems acetate, a specific volatile fatty acid, or a mixture of glucose and glutamate may be used [3,33,34,36]. These organic electron donors are thermodynamically favored by anode bacteria, as they provide more energy than inorganic electron donors. Nevertheless, as they are organic in nature, the biosensors can solely be used to sense BOD changes or toxicity, indicating that their sensing selectivity is limited. However, in some cases when proper acclimatization of the anode bacteria was achieved, the sensing was able reach certain specificity levels [33,34].

    Table 2. Some MFC systems operated with inorganic electron donors.
    MFC type Electron donor Configuration Electricity generation Operated as biosensor Reference
    Sulfide removing microbial fuel cell Sulfide coupled to acetate Square-type (modified two-chamber NCBE type) and tubular type Maximum current: 11 mA No [24]
    Power output: 37 mW L−1 NAC (20 mW L−1 TAC)
    Denitrifying sulfide removing microbial fuel cell Sulfide only Modified two-chamber NCBE type Maximum current: NA No [21]
    Power output: 2.80 ± 0.05 mW L−1 NAC
    Reduced inorganic sulfur compound (RISC) removing microbial fuel cell RISC (tetrathionate) Modified two-chamber NCBE type Maximum current: 0.39 mA* No [20,35]
    Power output: 1.7 mW L−1 TAC*
    Ammonia removing microbial fuel cell Ammonium Rotating-cathode type Maximum current: 0.078 ± 0.003 mA No [22]
    Power output: NA
    Iron-oxidizing microbial fuel cell (lithotrophic MFC) Ferrous iron (Fe2+); Manganese (II) (Mn2+) Modified two-chamber NCBE type Maximum current: 0.6 mA Yes [17,23]
    Power output: 2.56 mW L−1 NAC
    NAC: net anodic compartment; TAC: total anodic compartment; NA: not available; *: recalculated from the authors' calculation.
     | Show Table
    DownLoad: CSV

    2.3. Microbiology

    The role of the microbial source: Nguyen et al. (2015) proved that a microbial source used for inoculation is necessary to enrich a well- and stably-performing working bacterial community that can oxidize iron and produce electricity in a MFC [23]. According to them, the inoculum for enrichment should be taken from sites where clear indicators of metal metabolism are evident. After enrichment, the established reactor (the so-called lithotrophic MFC) is to be operated as an open system. In such a system, the mixed culture community, which is enriched from a natural microbial source, seems to enable a stable, long-term performance of the MFC [37,38]. Indeed, similar results from inoculation have been reported elsewhere, even in heterotrophic systems [39,40]. There was clear evidence that the inoculum selection could significantly affect the performance of MFCs in general and MFC-typed biosensors in particular [41,42,43].

    Microbial communities and typical microorganisms: By DNA analysis and fluorescent in situ hybridization (FISH) analysis, Nguyen et al. (2015) showed that bacteria in the anode compartment of a lithotrophic MFC-based biosensor were solely present in the suspension and did not tend to form a noticeable biofilm on the electrode surface [23]. Particularly, a clear increased presence of neutrophilic, iron-oxidizing bacteria was observed at the anode of the MFC, which suggests that the iron oxidation coupled to electricity generation of the MFC is likely linked to the activity of these bacteria [23]. Interestingly, Geobacter sp., Bacillus sp., and specifically Pseudomonas sp. were found to be dominant in the community. These bacteria, with the exception of Bacillus sp., have been discovered in many other bioelectrochemical systems and are considered key players in the electrochemical activity of the systems [9,44]. Thus, they are also believed to play important roles in the performance of the lithotrophic MFC, as “neutrophilic iron bacteria” [23]. Therefore, from the first glance, one may suppose that the microbial community of a lithotrophic MFC may have a high similarity to those of other MFC systems (including heterotrophic systems), but it actually does not, considering the possibility that the electrochemically active bacteria in a lithotrophic MFC can be so specialized in their lithotrophic metal-oxidizing capabilities. This possibility is due to the fact that Fe2+ was the favored substrate over organic electron donors such as acetate, lactate, or BOD materials (when present at non-excessive levels) [17]. Thus, it was suggested that the bacteria at the anode of the lithotrophic MFC may be novel species that are not well understood, or they are known species with unknown activities.


    2.4. Proposed electron transfer mechanisms

    It was found that iron-oxidizing bacteria are present in the anode microbial community of the lithotrophic MFC but they did not tend to form a noticeable biofilm on the electrode, which leads to a hypothesis that those bacteria are involved in the anode electron transfer but they do not directly transfer electrons to the electrode [23]. Furthermore, the dominance of Pseudomonas species in the anode community of the MFC also supports this hypothesis. Pseudomonas species are well known as electrochemically active heterotrophic bacteria that can self-produce electron mediators to reduce an electrode through oxidization of organic matter in heterotrophic MFCs [45,46]. Several Pseudomonas species have been also reported to be able to chemolithotrophically metabolize Fe2+ at neutral pH [47,48]. Therefore, considering the facts mentioned above, Nguyen et al. (2015) hypothesized that some Pseudomonas species could be actually the dominant “neutrophilic iron bacteria” in the anode of the lithotrophic MFC and can oxidize Fe2+, as well as transfer electrons to the anodic electrode via their self-produced mediators (Figure 1) [23]. Thus, in a lithotrophic MFC-based biosensor, the anode electron transfer is believed to be based on the indirect mechanism [45]. This mechanism is not new, but it should be noted that the self-mediated pseudomonads may also utilize an inorganic electron donor, such as Fe2+, to harvest energy- they are electrochemically active lithotrophs.

    Although the above-mentioned hypothesis of electron transfer mechanism is strongly supported by experimental data, one should not neglect a possibility that pseudomonads may utilize organic electron donors synthesized from the iron chemilithotrophy of certain neutrophilic iron oxidizing bacteria, or even “graze” on their cells (biomass). This is somewhat supported by our recent observation that after a significant period of operation (e.g. a year), the lithotrophic MFC could generate electrical current for a short time when no ferrous iron was supplied (unpublished data). Furthermore, the amount of energy harvested from the oxidation of ferrous iron at neutral pH is considerably too thermodynamically small to compensate for the expense of self-producing mediators. Therefore, some alternative electron transfer mechanisms for the anode reaction of the lithotrophic MFC-based biosensor may be hypothesized (Figure 1).

    Figure 1. The main hypothesis (A) and the alternative hypothesis (B) of electron transfer mechanism at the anode of the iron-oxidizing lithotrophic MFC (partially adopted from [23]). Notes: MED: mediator.


    2.5. Sensing performance


    2.5.1. The capability of the lithotrophic MFC as a sensor for iron and manganese

    The lithotrophic MFC, once enriched with iron-oxidizing bacteria, could be operated with anode solutions containing Fe2+ and having a pH 7 [23]. As reported by Tran et al. (2015), when operated with different concentrations of Fe2+ in the anode influent, the lithotrophic MFC generated electrical current and charge that were proportional to the concentration of Fe2+ from 5 mM to 20 mM (r2 = 0.98) [17]. This response was the same no matter if the concentrations of Fe2+ were tested in increasing or decreasing concentrations. Experimental results also showed that the MFC generated current only when Fe2+ was present in the anode buffer and that the generation of current is mostly due to biotic oxidation of Fe2+ [17]. Based on those findings, the authors suggested that the MFC could be used as a biosensor to detect iron, or even to measure the amount of ferrous iron (within a range) in a water sample having a neutral pH. Similar responses were also observed when the lithotrophic MFC was operated with Mn2+, but the range of Mn2+ concentration to which the MFC responded was limited to less than 3 mM. Thus, the capability of the MFC as a biosensor for manganese does not seem to be as efficient as that seen for iron. Tran et al. (2015) hypothesized that inhibitory effects of Mn2+ on the anode microorganisms might be the reason for the decreased performance.


    2.5.2. Sensitivity and detection limits

    The response time of the MFC (i.e. time for the current to reach a steady state in any test) was approximately 60 sec when the concentration of Fe2+ was step increased, while it took a period of one batch run (ca. 2 hrs) when the concentration of Fe2+ was step decreased. Thus Tran et al. (2015) claimed that the lithotrophic MFC-based biosensor has a relatively high sensitivity when sensing increasing concentrations of Fe2+, but its sensitivity may be reduced if decreasing concentrations are to be monitored [17]. By testing the concentrations of Fe2+ from 1 to 5 mM, Tran et al. (2015) also determined that the lower detection limit of the lithotrophic MFC-based biosensor for Fe2+ was 3 mM. Furthermore, as the device did not respond to changes in Fe2+ concentration exceeding 20 mM—this concentration was determined as the upper detection limit. As for manganese, although the lower detection limit of the device was about 1 mM, the upper detection limit was determined to be only 3 mM, indicating that the anode bacteria might be more susceptible to Mn2+.


    2.5.3. Endurance

    It was shown that the lithotrophic MFC could endure starvation (being operated without feeding) for a period of up to 14 days and fully restore its capability of generating electricity after starvation [17]. On the other hand, the response of the system to changes in the concentration of Fe2+ remained unchanged after 12 months of operation, although a generated current reduced by 25% could be observed. Therefore, the lithotrophic MFC-based iron sensor can be considered to have a stable performance and thus can be used for long term application.


    2.5.4. Specificity

    It should be noted that some metal ions, such as Ni2+ and Pb2+, could act as possible inhibitors on the anodic microorganisms in the lithotrophic MFC-based biosensor but not as competing electron donors [17]. This finding suggests that among metals, the device responds more specifically to iron and manganese. In fact, the anodic microorganisms in the MFC could use organic compounds such as acetate, lactate, or glucose/glutamate mixtures as electron donors [17]. However, it is remarkable that these organic electron donors, if not present at excessive levels, were not favored over Fe2+. Thus, it was concluded that, when co-present with Fe2+ in the anode, organic compounds did not interfere with the response of the MFC to the presence of Fe2+. Altogether, the current research suggests that the lithotrophic MFC-based biosensor has a remarkably high specificity to iron.

    Regarding heterotrophic MFC-based systems, as the result of extensive study thus far, their sensing performances have been seemingly much more optimized. As mentioned earlier, these systems can be used most efficiently to monitor BOD and toxicity of wastewater. Thus, specificity is not a serious requirement for these devices, although selective detection of certain organic compounds could be achieved through proper acclimatization of the anode bacterial communities [33,34]. With respect to detection range, the first systems are able to respond well to BOD concentrations ranging from 3-150 mg L−1 [3,26,27] and the upper limit was later even improved up to 350 mg L−1 with a single chamber configuration [30]. The systems could also detect a variety of toxicants including phenolic or halogenated compounds and some heavy metals [5,6,30,32] with a high sensitivity, particularly when the MFC was miniaturized. According to di Lorenzo et al. (2014) [30], a small-scale MFC-based biosensor could detect cadmium at a concentration as low as 1 µg L−1 with a detection time of 3 min. It can be noted that the detection range and sensitivity of the heterotrophic systems are considerably suitable for practical application [19], which is an advantage over the lithotrophic counterparts, although the research of which is still in an early phase.


    2.6. Effect of operational parameters

    When applying an iron biosensor in practice, operational factors can affect its performance. Hence, Tran et al. (2015) investigated the effect of pH of the sample, buffer strength of the anolyte, surrounding temperature, and external resistance on the performance of the lithotrophic MFC-based biosensor [17]. Their experimental results showed that these parameters affect the performance of the lithotrophic MFC-based biosensor at different degrees.


    2.6.1. pH of the sample and buffer strength

    Although it is proposed that the lithotrophic MFC-based biosensor is always operated in a manner such that the anolyte is buffered, pH of the sample can still slightly affect its performance. It was clear that samples with pH values falling in the range of 7-9 could lead to approximately 20% higher levels of the current generated by the device, in comparison with those with other pH values. In order to decrease material cost when applying the lithotrophic MFC-based biosensor in practice, the amount of anode buffer should be reduced. As reported by Tran et al. (2015), a 10-fold diluted buffer only reduced the generation of electricity by about 15%. Thus the effect of the buffer strength did not appear to be critical and reducing the amount of buffer used in practice is recommended.

    For heterotrophic systems, similar effects of pH of the sample can be expected for buffered anolytes [49], but for field applications with real wastewaters, buffer strength of the anolyte can significantly affect the performance of the devices and should be carefully controlled [50]. Specifically, according to Gil et al. (2003), certain buffer strength is required to reduce the proton limitation in a MFC-based BOD sensor [49]. The fact that the performance of the lithotrophic MFC is less affected by buffer strength than pH is relatively striking. Possibly, the electrical current generated in this system is not great enough to be limited by proton transfer.


    2.6.2. Surrounding temperature

    Understanding the effect of surrounding temperature on the performance of the lithotrophic MFC-based biosensor is also very important for practical applications. Surprisingly, the optimal range of surrounding temperature for the device to function is 30-40 °C, which is quite narrow. When operated at temperatures outside this range, the current generated by the MFC was 2- to 3-fold lower [17]. The narrow optimal range of temperature will likely limit the deployment of the equipment in reality.

    Temperature also affects the performance of heterotrophic MFC-based biosensors in a similar manner. According to di Lorenzo (2009), MFC-typed BOD/COD sensors could give a higher current and a faster response when operated at temperatures higher than 30 °C. This temperature range was also considered optimal for a wastewater-fed single-chamber MFC, although decreasing the temperature from 32 °C to 20 °C did not have a significant effect on the performance of the MFC [51]. These similar responses to temperature in both heterotrophic and lithotrophic MFC systems is reasonable, as the MFCs are normally operated under ambient temperatures and thus mesophilic anode bacteria can be expected to be enriched.


    2.6.3. External resistance

    External resistance is a key parameter limiting the performance of many MFC systems [14,25]. In a lithotrophic MFC-based biosensor, the higher the external resistance, the lower the current that could be generated, but the relationship between these two parameters was not inversely linear [17]. The relationship is similar to those observed in other heterotrophic MFC systems, suggesting that external resistance can significantly affect the performance of the lithotrophic MFC-based biosensor. Furthermore, it has been shown that the magnitude of external resistance can also affect the response time and the recovery time of a MFC [52]. For instance, di Lorenzo et al. (2009) observed that the response time of a BOD and toxicity sensor could be reduced by 67% when the external resistance decreased from 500 Ω to 50 Ω [4]. Stein et al. (2012) also found that a lower external resistance resulted in a clearer and more sensitive response while a higher external resistance could help the MFC recover more quickly after change. Lithotrophic MFCs, however, always responded immediately (e.g. in less than 60 sec) to any change in the concentration of Fe2+ in the anolyte, regardless of the magnitude of the resistance being tested [17]. Thus, for this system, operators only need to select an external resistance that enables the generation of the highest current so that changes of the current are most apparent.


    3. Challenges and propositions to overcome

    It has been known that the performance of MFCs is limited by several factors, including the microbial activity, the electron transfer process, the internal resistance of the device, and particularly the cathode reaction rate [11,14,49,53]. As evidenced, these limiting factors also affect the performance of the lithotrophic MFC-based biosensor. However, considering the application aim of using the device as a biosensor, it is the stability of the electrical signal that is required, not a high power output. Factors affecting the stability of the electrical signal can reasonably be identified as the microbial activity and the electron transfer process, rather than the other factors listed above. Therefore, in order to improve the performance of a lithotrophic MFC for use as an iron biosensor, microbial activity and the electron transfer should be addressed.


    3.1. Selection of the inoculating sources

    As mentioned above, in order to have a stable and well-performing microbial community that enables a stable electricity generation of the lithotrophic MFC, the selection of the microbial source for inoculation is critical. As suggested by Nguyen et al. (2015), inocula from natural sources which show clear indicators of iron metabolism can potentially provide a diverse and balanced collection of lithotrophic bacteria that can be enriched and function stably in a MFC [23]. Indeed, most well-performing and stable open-system MFCs are operated with mixed cultures enriched from natural microbial sources [37,38]. In principle, this is a logical requirement, particularly for heterotrophic systems, as the diversity of the enriched microbial communities can handle the diversity of substrates to enable the performance stability of the systems. Thus, a diverse mixed culture in a lithotrophic MFC might be even better for its sensing performance. The enrichment and stabilization of a working community from a natural microbial source may require more time, but this is not considered as a critical matter in practice.


    3.2. Performance stability

    Even when the lithotrophic MFC is in steady state, its generated current may decrease after a significant time of operation (e.g. 12 months), although the response of the device to Fe2+ is unchanged, as mentioned earlier. In addition, the levels of the currents generated by different MFCs operated under the same conditions are not always equivalent. This is partially due to the effects of operational parameters, as discussed above. It should be recalled that different operational conditions affect the performance of the MFC at various degrees. Indeed, fluctuating performance was also observed with heterotrophic MFC-based sensors and a strictly controlled operation was recommended to reduce background [36]. Another potential factor affecting the long-term performance of the lithotrophic MFC-based biosensor can be insoluble ferric products precipitating on the anode surface and gradually hindering the electron transfer. Furthermore, in a long-term use of the system, electrochemically active heterotrophs may grow on organic contaminants in the sample and will likely alter the activity of the anode microbial consortium, as well as the electrical signal. The mentioned issues can be challenging if the sensing mechanism is based on the absolute value of the electrical current generated. For the lithotrophic MFC, one suggested solution to overcome this challenge is a calibration before using the device for any measurement [17].

    Tran et al. (2015) also posed some propositions for improving the stability of the performance of the lithotrophic MFC-based biosensor. The first proposition is to replace the anode material with a material that can stimulate biofilm formation, such as graphite felt. The first-version system, operated with graphite granules as the anode material, seems to favor suspending bacteria that electrochemically function through self-produced mediators, and thus hardly achieved a steady performance due to anolyte wash-out or unstable bacterial density [17]. Graphite granules are known to have low porosities [54], which may lead to limited biofilm growth on them. Electrochemically active bacteria transferring electrons to the electrode via self-produced mediators have been reported to be associated solely with MFC systems operated with graphite granules as the anode material [45,55]. Therefore, replacing graphite granules with graphite felts would likely result in less suspended electrochemically active bacteria and promote more biofilm formation in the anode. Other MFC systems operated with graphite felts as anode materials usually harbor biofilms formed on their anode surfaces [37,56,57]. Such a biofilm would ensure a stable microbial community that can be long-lasting and have a steady function [38]. Furthermore, the biofilm could be strengthened if the MFC is operated in continuous mode, which is the second proposition for improving the performance of the system. It is believed that a continuous mode might ensure the generation of a continuous current that is stable (much less affected by environmental factors than the batch-type current) and reflect the change of substrate concentration in the anolyte in a real-time manner [3]. Hence, the operation of the lithotrophic MFC in the continuous mode, combined with the use of graphite felt as its anode material, is expected to improve the stability of its performance and thus its iron sensing capability.


    3.3. Limited detection range

    While the detection range is not a matter to heterotrophic systems, it is a limitation of the first version of the lithotrophic MFC-based biosensor. The concentration detection range of the lithotrophic MFC for Fe2+ is 3-20 mM and that for Mn2+ is about 1-3 mM [17]. These narrow ranges might also limit the sensing capability of the device. Particularly, as the common concentration of Fe2+ in ground water samples falls below 3 mM, the lower detection limit of the MFC should be reduced. Further improvements are thus required and should focus on this matter. One possible improvement can be to reduce the volume of the anode chamber. Previous studies have shown that reducing the volume of the anode chamber significantly improved the sensitivity and detection limit of a BOD sensor [4]. Consequently, the volume of the anode chamber might be a cause for the high lower detection limit of the lithotrophic MFC-based biosensor for Fe2+. Therefore, experiments examining smaller volumes of the anode chamber should be conducted to investigate whether the detection range of the device can be expanded. In addition, as mentioned above, a sensor-type design can increase the response sensitivity and accuracy of MFC-typed biosensors and should be also applied for the lithotrophic MFC-based biosensor.


    4. Opportunities

    The people in rural areas in developing countries (such as Vietnam), having no access to public water supply and often use water from underground sources without being aware of its quality. For example, it was reported that of more than 16 millions people living on the Red River delta areas in northern Vietnam, 11 million have no access to clean water [58]. The water from underground sources can be contaminated with metals such as iron and manganese, which can cause several physiological malfunctions to the human body following exposure [59]. Populations in remote areas are in need of a method to quickly assess the presence of these toxic metals in their water; unfortunately, the current methods for the detection of the metals are mostly based on chemical tests that can be done only in laboratories or by using kits that are time-consuming, not environment-friendly, or not cost-effective. Hence, an on-site biosensor to detect metals such as iron and manganese in water sources would be contributive to a sustainable life of people in rural areas in developing countries.

    Although still facing some challenges, as discussed by Tran et al. (2015), the potential application of the lithotrophic MFCs as metal biosensors is promising. As discussed earlier, the device can produce electrical currents only when ferrous iron is present and a linear correlation between the current and the concentration of Fe2+ could be applied within the concentration range of 3-20 mM (r2 = 0.98). Moreover, other possible electron donors cannot compete with ferrous iron at the same level. This specificity in detecting iron is attributed to the specific iron-oxidizing bacterial consortium enriched in the MFC [17]. Therefore, evidence that the device can detect iron in water samples (based on the appearance of electrical current) is considered reliable. The presence of ferrous iron will reflect the presence of iron in the samples, which in turn usually indicates the co-presence of other metals [58]. Thus, the detection of iron by the lithotrophic MFC-based biosensor can be also regarded as a warning about the presence of other metals in a water sample.

    Simple handling is also an application advantage of the system. As mentioned previously, the MFC can be operated as an open-system biosensor as long as a suitable microbial community is enriched at the anode. As an open system, the device does not require special care or complicating renewing procedures. It is even more notable that the device can be operated with neutral-pH water samples, which reduces much of the work possibly required for pH adjustment if an acidic condition is needed. This is because the MFC is distinctively operated with neutrophilic iron bacteria, rather than the more popular acidophilic bacteria. Therefore, it is easier and more convenient for users to deploy the device in field applications.

    Although the high [Fe2+] detection range can be considered a limitation of the MFC, it also implies that the device can be used to detect waters over-polluted with Fe. The device will be particularly helpful in quickly assessing any Fe or Fe2+ pollution situation. Quick assessment due to the quick response to Fe2+ of the lithotrophic MFC-based biosensor and its portability are also two other advantages of this system. Indeed, the small size of the device (only about 12 cm × 12 cm × 5 cm) [23] makes it portable. Portability and quick response suggest the prospect of innovating the device toward a portable quick-kit for the detection of iron in water samples. Commercial kits for quick detection of ferrous iron are available but they are costly (ca. 20USD/kit). The lithotrophic MFC-based biosensor can not only quickly sense the presence of iron but may also be reused unless the reactor is damaged, which making it more cost-efficient. A thorough comparison of lithotrophic MFC-based iron sensors with other technologies used for the same purpose is shown in Table 3.

    Table 3. The comparison of the lithotrophic MFC-based biosensor to competing technologies.
    Sensing platform Specificity Sensitivity & detection limits Detection time Portability Handling Cost Reusability Other opportunities
    The lithotrophic MFC-based biosensor Relatively high Relatively high; detection range: 3-20 mM Short (60 sec) Yes Simple; no special care Low Yes; for long (until the device is damaged) Bioremediation and on-line monitoringof metals
    Commercial quick detection kits Very high Very high; broad detection range Short Yes Simple High No No
    Laboratory analytical tests Very high Very high; broad detection range Long (time is required for sampling, sample processing and analysis) No (samples should be brought to laboratory) Not simple; skilled personnel required High No No
     | Show Table
    DownLoad: CSV

    The linear relationship between the Fe2+ concentration and the electrical signal produced by the lithotrophic MFC suggests that the device can be used as a biosensor not only to detect iron, but also to monitor the amount of iron. If the device can be operated in a continuous mode, real-time monitoring of the Fe2+ concentration will be even feasible. However, in order to realize those application potentials, several limitations need to be overcome, as already discussed.

    An extended application potential of the lithotrophic MFC can be bioremediation of metals [23]. In fact, bioremediation using MFC and MFC-related systems has been reported by a number of publications [60,61,62,63]. In those reports, the bioremediation is based on exploiting the cathode reactions of the MFCs to reduce oxidized forms of metals. In contrast, the lithotrophic MFC can offer oxidation-based bioremediation. Potentially, the system could be used for an accelerated bioremediation of iron in water samples, as the soluble ferrous salts could be converted to insoluble ferric salts by the activity of the anode electroactive iron-oxidizing community.


    5. Conclusions

    Several MFC systems involving bacterial lithotrophy have been reported but only those operated with enriched iron-oxidizing bacteria can be considered fully lithotrophic systems that have the potential to be used as biosensors for iron or metals in general. The system is well established and characterized in terms of configuration, fabrication, and operational parameters. It shares some common features with the heterotrophic counterparts, but also has its own distinctive properties. The properties of an open-system, the operation at neutral pH, the relatively high specificity in detecting Fe2+, portability, and reusability are notable characteristics of the device and also the advantages that differentiate it from competing sensing technologies. However, in order to realize the practical application of the device, challenges to maintain a stable microbial community in the anode, a stable performance, and a broader detection range should be overcome by future research.


    Conflict of interest

    The author declares no conflicts of interest in this article.


    [1] Lei Y, Chen W, Mulchandani A (2006) Microbial biosensors. Anal Chim Acta 568: 200–210. doi: 10.1016/j.aca.2005.11.065
    [2] D'Souza SF (2001) Microbial biosensors. Biosens Bioelectron 16: 337–353. doi: 10.1016/S0956-5663(01)00125-7
    [3] Chang IS, Jang JK, Gil GC, et al. (2004) Continuous determination of biochemical oxygen demand using microbial fuel cell type biosensor. Biosens Bioelectron 19: 607–613. doi: 10.1016/S0956-5663(03)00272-0
    [4] Di Lorenzo M, Curtis TP, Head IM, et al. (2009) A single-chamber microbial fuel cell as a biosensor for wastewaters. Water Res 43: 3145–3154. doi: 10.1016/j.watres.2009.01.005
    [5] Stein NE, Hamelers HMV, van Straten G, et al. (2012) On-line detection of toxic components using a microbial fuel cell-based biosensor. J Process Contr 22: 1755–1761. doi: 10.1016/j.jprocont.2012.07.009
    [6] Lee H, Yang W, Wei X, et al. (2015) A microsized microbial fuel cell based biosensor for fast and sensitive detection of toxic substances in water. IEEE 2015: 573–576.
    [7] Webster DP, TerAvest MA, Doud DFR, et al. (2014) An arsenic-specific biosensor with genetically engineered Shewanella oneidensis in a bioelectrochemical system. Biosens Bioelectron 62: 320–324. doi: 10.1016/j.bios.2014.07.003
    [8] Liu Z, Liu J, Zhang S, et al. (2011) Microbial fuel cell based biosensor for in situ monitoring of anaerobic digestion process. Bioresource Technol 102: 10221–10229. doi: 10.1016/j.biortech.2011.08.053
    [9] Rabaey K, Rodriguez J, Blackall LL, et al. (2007) Microbial ecology meets electrochemistry: electricity-driven and driving communities. ISME J 1: 9–18. doi: 10.1038/ismej.2007.4
    [10] Pham TH, Aelterman P, Verstraete W (2009) Bioanode performance in bioelectrochemical systems: recent improvements and prospects. Trends Biotechnol 27: 168–178. doi: 10.1016/j.tibtech.2008.11.005
    [11] Mohan SV, Velvizhi G, Modestra JA, et al. (2014) Microbial fuel cell: Critical factors regulating bio-catalyzed electrochemical process and recent advancements. Renew Sust Energ Rev 40: 779–797. doi: 10.1016/j.rser.2014.07.109
    [12] Dávila D, Esquivel JP, Sabaté N, et al. (2011) Silicon-based microfabricated microbial fuel cell toxicity sensor. Biosens Bioelectron 26: 2426–2430. doi: 10.1016/j.bios.2010.10.025
    [13] Lovley DR, Nevin KP (2011) A shift in the current: New applications and concepts for microbe-electrode electron exchange. Curr Opin Biotech 22: 441–448. doi: 10.1016/j.copbio.2011.01.009
    [14] Kim BH, Chang IS, Gadd GM (2007) Challenges in microbial fuel cell development and operation. Appl Microbiol Biot 76: 485–494. doi: 10.1007/s00253-007-1027-4
    [15] Rabaey K, Rozendal RA (2010) Microbial electrosynthesis-revisiting the electrical route for microbial production. Nat Rev Microbiol 8: 706–716. doi: 10.1038/nrmicro2422
    [16] Arends JB, Verstraete W (2012) 100 years of microbial electricity production: three concepts for the future. Microb Biotechnol 5: 333–346. doi: 10.1111/j.1751-7915.2011.00302.x
    [17] Tran PHN, Luong TTT, Nguyen TTT, et al. (2015) Possibility of using a lithotrophic iron-oxidizing microbial fuel cell as a biosensor for detecting iron and manganese in water samples. Environ Sci Proc Impacts 17: 1806–1815. doi: 10.1039/C5EM00099H
    [18] Pant D, Van Bogaert G, Diels L, et al. (2010) A review of the substrates used in microbial fuel cells (MFCs) for sustainable energy production. Bioresource Technol 101: 1533–1543. doi: 10.1016/j.biortech.2009.10.017
    [19] Yang H, Zhou M, Liu M, et al. (2015) Microbial fuel cells for biosensor applications. Biotechnol Lett 37: 2357–2364. doi: 10.1007/s10529-015-1929-7
    [20] Sulonen MLK, Lakaniemi AM, Kokko ME, et al. (2016) Long-term stability of bioelectricity generation coupled with tetrathionate disproportionation. Bioresource Technol 216: 876–882. doi: 10.1016/j.biortech.2016.06.024
    [21] Zhong L, Zhang S, Wei Y, et al. (2017) Power recovery coupled with sulfide and nitrate removal in separate chambers using a microbial fuel cell. Biochem Eng J 124: 6–12. doi: 10.1016/j.bej.2017.04.005
    [22] He Z, Kan J, Wang Y, et al. (2009) Electricity production coupled to ammonium in a microbial fuel cell. Environ Sci Technol 43: 3391–3397. doi: 10.1021/es803492c
    [23] Nguyen TT, Luong TTT, Tran PHN, et al. (2015) A lithotrophic microbial fuel cell operated with pseudomonads-dominated iron-oxidizing bacteria enriched at the anode. Microb Biotechnol 8: 579–589. doi: 10.1111/1751-7915.12267
    [24] Rabaey K, Van de Sompel K, Maignien L, et al. (2006) Microbial fuel cells for sulfide removal. Environ Sci Technol 40: 5218–5224. doi: 10.1021/es060382u
    [25] Logan BE, Hamelers B, Rozendal R, et al. (2006) Microbial fuel cells: Methodology and technology. Environ Sci Technol 40: 5181–5192. doi: 10.1021/es0605016
    [26] Kim M, Youn SM, Shin SH, et al. (2003) Practical field application of a novel BOD monitoring system. J Environ Monitor 5: 640–643. doi: 10.1039/b304583h
    [27] Kim BH, Chang IS, Gil GC, et al. (2003) Novel BOD (biological oxygen demand) sensor using mediator-less microbial fuel cell. Biotechnol Lett 25: 541–545. doi: 10.1023/A:1022891231369
    [28] Kang KH, Jang JK, Pham TH, et al. (2003) A microbial fuel cell with improved cathode reaction as a low biochemical oxygen demand sensor. Biotechnol Lett 25: 1357–1361. doi: 10.1023/A:1024984521699
    [29] Liu B, Lei Y, Li B (2014) A batch-mode cube microbial fuel cell based "shock" biosensor for wastewater quality monitoring. Biosens Bioelectron 62: 308–314. doi: 10.1016/j.bios.2014.06.051
    [30] Di Lorenzo M, Thomson AR, Schneider K, et al. (2014) A small-scale air-cathode microbial fuel cell for on-line monitoring of water quality. Biosens Bioelectron 62: 182–188. doi: 10.1016/j.bios.2014.06.050
    [31] Ringeisen BR, Henderson E, Wu PK, et al. (2006) High power density from a miniature microbial fuel cell using Shewanella oneidensis DSP10. Environ Sci Technol 40: 2629–2634. doi: 10.1021/es052254w
    [32] Kim M, Hyun MS, Gadd GM, et al. (2007) A novel biomonitoring system using microbial fuel cells. J Environ Monitor 9: 1323–1328. doi: 10.1039/b713114c
    [33] Quek SB, Cheng L, Cord-Ruwisch R (2015) Microbial fuel cell biosensor for rapid assessment of assimilable organic carbon under marine conditions. Water Res 77: 64–71. doi: 10.1016/j.watres.2015.03.012
    [34] Kaur A, Kim JR, Michie I, et al. (2013) Microbial fuel cell type biosensor for specific volatile fatty acids using acclimated bacterial communities. Biosens Bioelectron 47: 50–55. doi: 10.1016/j.bios.2013.02.033
    [35] Ni G, Christel S, Roman P, et al. (2016) Electricity generation from an inorganic sulfur compound containing mining wastewater by acidophilic microorganisms. Res Microbiol 167: 568–575. doi: 10.1016/j.resmic.2016.04.010
    [36] Stein NE, Hamelers HVM, Buisman CNJ (2010) Stabilizing the baseline current of a microbial fuel cell-based biosensor through overpotential control under non-toxic conditions. Bioelectrochemistry 78: 87–91. doi: 10.1016/j.bioelechem.2009.09.009
    [37] Kim BH, Park HS, Kim HJ, et al. (2004) Enrichment of microbial community generating electricity using a fuel-cell-type electrochemical cell. Appl Microbiol Biot 63: 672–681. doi: 10.1007/s00253-003-1412-6
    [38] Logan BE, Regan JM (2006) Electricity-producing bacterial communities in microbial fuel cells. Trends Microbiol 14: 512–518. doi: 10.1016/j.tim.2006.10.003
    [39] Liu Z, Li H, Liu J, et al. (2008) Effects of inoculation strategy and cultivation approach on the performance of microbial fuel cell using marine sediment as bio-matrix. J Appl Microbiol 104: 1163–1170. doi: 10.1111/j.1365-2672.2007.03643.x
    [40] Tran P, Nguyen L, Nguyen H, et al. (2016) Effects of inoculation sources on the enrichment and performance of anode bacterial consortia in sensor typed microbial fuel cells. AIMS Bioeng 3: 60–74. doi: 10.3934/bioeng.2016.1.60
    [41] Mathuriya AS (2013) Inoculum selection to enhance performance of a microbial fuel cell for electricity generation during wastewater treatment. Environ Technol 34: 1957–1964. doi: 10.1080/09593330.2013.808674
    [42] Vázquez-Larios AL, Poggi-Varaldo HM, Solorza-Feria O, et al. Effect of type of inoculum on microbial fuel cell performance that used RuxMoySez as cathodic catalyst. Int J Hydrogen Energ 40: 17402–17412.
    [43] Hsieh MC, Chung YC (2014) Measurement of biochemical oxygen demand from different wastewater samples using a mediator-less microbial fuel cell biosensor. Environ Technol 35: 2204–2211. doi: 10.1080/09593330.2014.898700
    [44] Logan BE, Regan JM (2006) Microbial challenges and applications. Environ Sci Technol 40: 5172–5180. doi: 10.1021/es0627592
    [45] Rabaey K, Boon N, Siciliano SD, et al. (2004) Biofuel cells select for microbial consortia that self-mediate electron transfer. Appl Environ Microb 70: 5373–5382. doi: 10.1128/AEM.70.9.5373-5382.2004
    [46] Rabaey K, Boon N, Hofte M, et al. (2005) Microbial phenazine production enhances electron transfer in biofuel cells. Environ Sci Technol 39: 3401–3408. doi: 10.1021/es048563o
    [47] Sudek LA, Templeton AS, Tebo BM, et al. (2009) Microbial Ecology of Fe (hydr)oxide Mats and Basaltic Rock from Vailulu'u Seamount, American Samoa. Geomicrobiol J 26: 581–596. doi: 10.1080/01490450903263400
    [48] Straub KL, Benz M, Schink B, et al. (1996) Anaerobic, nitrate-dependent microbial oxidation of ferrous iron. Appl Environ Microbiol 62: 1458–1460.
    [49] Gil GC, Chang IS, Kim BH, et al. (2003) Operational parameters affecting the performance of a mediator-less microbial fuel cell. Biosens Bioelectron 18: 327–334. doi: 10.1016/S0956-5663(02)00110-0
    [50] Kim BH, Chang IS, Moon H (2006) Microbial fuel cell-type biochemical oxygen demand sensor. Studies 3.
    [51] Liu H, Cheng SA, Logan BE (2005) Power generation in fed-batch microbial fuel cells as a function of ionic strength, temperature, and reactor configuration. Environ Sci Technol 39: 5488–5493. doi: 10.1021/es050316c
    [52] Stein NE, Hamelers HVM, Buisman CNJ (2012) The effect of different control mechanisms on the sensitivity and recovery time of a microbial fuel cell based biosensor. Sensor Actuat B-Chem 171: 816–821.
    [53] Pham TH, Rabaey K, Aelterman P, et al. (2006) Microbial fuel cells in relation to conventional anaerobic digestion technology. Eng Life Sci 6: 285–292. doi: 10.1002/elsc.200620121
    [54] Logan B, Cheng S, Watson V, et al. (2007) Graphite fiber brush anodes for increased power production in air-cathode microbial fuel cells. Environ Sci Technol 41: 3341–3346. doi: 10.1021/es062644y
    [55] Rabaey K, Clauwaert P, Aelterman P, et al. (2005) Tubular microbial fuel cells for efficient electricity generation. Environ Sci Technol 39: 8077–8082. doi: 10.1021/es050986i
    [56] Bond DR, Lovley DR (2003) Electricity production by Geobacter sulfurreducens attached to electrodes. Appl Environ Microb 69: 1548–1555. doi: 10.1128/AEM.69.3.1548-1555.2003
    [57] Liu H, Ramnarayanan R, Logan BE (2004) Production of electricity during wastewater treatment using a single chamber microbial fuel cell. Environ Sci Technol 38: 2281–2285. doi: 10.1021/es034923g
    [58] Winkel LHE, Trang PTK, Lan VM, et al. (2011) Arsenic pollution of groundwater in Vietnam exacerbated by deep aquifer exploitation for more than a century. P Natl Acad Sci USA 108: 1246–1251. doi: 10.1073/pnas.1011915108
    [59] Wasserman GA, Liu X, Parvez F, et al. (2006) Water manganese exposure and children's intellectual function in Araihazar, Bangladesh. Environ Health Persp 114: 124–129.
    [60] Habibul N, Hu Y, Sheng GP (2016) Microbial fuel cell driving electrokinetic remediation of toxic metal contaminated soils. J Hazard Mater 318: 9–14. doi: 10.1016/j.jhazmat.2016.06.041
    [61] Li Y, Wu Y, Liu B, et al. (2015) Self-sustained reduction of multiple metals in a microbial fuel cell-microbial electrolysis cell hybrid system. Bioresource Technol 192: 238–246. doi: 10.1016/j.biortech.2015.05.030
    [62] Shen J, Huang L, Zhou P, et al. (2017) Correlation between circuital current, Cu(II) reduction and cellular electron transfer in EAB isolated from Cu(II)-reduced biocathodes of microbial fuel cells. Bioelectrochemistry 114: 1–7. doi: 10.1016/j.bioelechem.2016.11.002
    [63] Sophia AC, Saikant S (2016) Reduction of chromium(VI) with energy recovery using microbial fuel cell technology. J Water Process Eng 11: 39–45. doi: 10.1016/j.jwpe.2016.03.006
  • This article has been cited by:

    1. Sara Amiri Fahliyani, Ali Asghar Rastegari, Ajar Nath Yadav, Neelam Yadav, 2020, 9780128205280, 43, 10.1016/B978-0-12-820528-0.00005-3
    2. Charles E. Turick, Sirivatch Shimpalee, Pongsarun Satjaritanun, John Weidner, Scott Greenway, Convenient non-invasive electrochemical techniques to monitor microbial processes: current state and perspectives, 2019, 103, 0175-7598, 8327, 10.1007/s00253-019-10091-y
    3. Lola Gonzalez Olias, Mirella Di Lorenzo, Microbial fuel cells for in-field water quality monitoring, 2021, 11, 2046-2069, 16307, 10.1039/D1RA01138C
    4. S. Nalini, S. Sathiyamurthi, P. Ramya, R. Sivagamasundari, K. Mythili, M. Revathi, 2023, 9781394166244, 169, 10.1002/9781394167135.ch8
  • Reader Comments
  • © 2018 the Author(s), licensee AIMS Press. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0)
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Metrics

Article views(4633) PDF downloads(850) Cited by(4)

Article outline

Figures and Tables

Figures(1)  /  Tables(3)

Other Articles By Authors

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return

Catalog